the signal to resample
the resampling factor, where values greater than one mean the signal is stretched (sampling-rate increases or pitch lowers) and values less than one mean the signal is condensed (sampling-rate decreases or pitch rises)
the minimum expected resampling factor, which controls
the amount of buffering needed for the input signal. This is used at
initialization time only. The default
value of zero makes the UGen settles on the first factor
value encountered.
It is possible to use a value actually higher than the lowest provided
factor
, in order to limit the buffer usage. In that case, the FIR anti-aliasing
filter will be truncated.
the FIR anti-aliasing roll-off width
the FIR windowing function's parameter
the number of zero-crossings in the truncated and windowed sinc FIR.
the resampling factor, where values greater than one mean the signal is stretched (sampling-rate increases or pitch lowers) and values less than one mean the signal is condensed (sampling-rate decreases or pitch rises)
the signal to resample
the FIR windowing function's parameter
Abstract method which must be implemented by creating the actual UGen
s
during expansion.
the minimum expected resampling factor, which controls the amount of buffering needed for the input signal.
the minimum expected resampling factor, which controls
the amount of buffering needed for the input signal. This is used at
initialization time only. The default
value of zero makes the UGen settles on the first factor
value encountered.
It is possible to use a value actually higher than the lowest provided
factor
, in order to limit the buffer usage. In that case, the FIR anti-aliasing
filter will be truncated.
the FIR anti-aliasing roll-off width
the number of zero-crossings in the truncated and windowed sinc FIR.
A band-limited resampling UGen.
It uses an internal table for the anti-aliasing filter. Table resolution is currently fixed at 4096 filter samples per zero crossing and linear interpolation in the FIR table, but the total filter length can be specified through the
zeroCrossings
parameter. Note: If filter parameters are changed, the table must be recalculated which is very expensive. However,factor
modulation is efficient.Note: Unlike most other UGens, all parameters but
in
are read at "output rate". That is particular important forfactor
modulation. For each frame output, one frame fromfactor
is consumed.the signal to resample
the resampling factor, where values greater than one mean the signal is stretched (sampling-rate increases or pitch lowers) and values less than one mean the signal is condensed (sampling-rate decreases or pitch rises)
the minimum expected resampling factor, which controls the amount of buffering needed for the input signal. This is used at initialization time only. The default value of zero makes the UGen settles on the first
factor
value encountered. It is possible to use a value actually higher than the lowest providedfactor
, in order to limit the buffer usage. In that case, the FIR anti-aliasing filter will be truncated.the FIR anti-aliasing roll-off width
the FIR windowing function's parameter
the number of zero-crossings in the truncated and windowed sinc FIR.